Pre-Engineered Buildings (PEB)
Pre- engineered buildings offer ultimate design flexibility and an extremely short construction time right from initial design to completion. They are supplied as a fully finished product along with steel structure, building accessories and roof cladding. They require no on-site fabrication or welding – they can simply be bolted together as per specifications.
Advantages
Pre- engineered buildings offer ultimate design flexibility and an extremely short construction time right from initial design to completion.
The Most Common Applications Of
Pre-engineered Buildings Are:
Warehouses
Industrial Buildings
Factories
Sports Complex / Stadiums
Multi Stored Buildings
Cold Storages
Heavy Industries
Super Markets
Airport Structures
Work Shops
Showrooms
Office Buildings
Distribution Centers
High Rise Structures
Primary Frame System
Primary members are the main steel frames of PEB. The main frames include columns, rafters, crane beams, mezzanine beams and other supporting members. The sections are fabricated with High strength steel plates using the state-of-the-art manufacturing technology.
Types of Main Frames
FRAME SHAPE | FRAME TYPE | RECOMMONDED SPAN RANGE | REMARKS |
---|---|---|---|
Rigid Frame Clear Span | 20-40M | Suitable for ware houses, good owns, work shops industrial buildings having clear span requirement | |
Rigid Frame Clear Span-1 | 30-50M | Suitable for large span building without a valley gutter | |
Rigid Frame Clear Span-2 | 46-60M | For span greater than 48M it is economical to go for RFMS-2 frame than RFMS-1 | |
Rigid Frame Clear Span-3 | 50-75M | They are economical to go for RFMS-2 for span greater tha 72M | |
Rigid Frame Lean To | 6-18M | Suitable for extension of existing buildings | |
Single Sloped Building | 15-30M | Suitable for small spans with drainage facility to sigle side | |
Rigid Frame Multi Gable-1 | 50-100M | Economical tha RMFS-1 but with valley Gutter | |
Rigid Frame Multi Gable-2 | 80-120M | Economical tha RMFS-1 but with valley Gutter |
Secondary Members
Purlins, Girts, Eave struts, anchor bolts and brace rods are secondary members which are used for the support of roof and wall panels. Purlins are used on roof, girts are used on wall and Eave struts are used at intersection of roof and wall panels.
C&z Sections
- Thickness Range – 1.5 mm to 3.0 mm
- Profile Width – 200 mm to 300 mm
- Material Finish – Pre- Galvanized (120 GSM/180 GSM/275 GSM)
Roof & Wall Sheeting
Paramount Roof & Wall Sheeting
Roof and Wall panels used are profiled steel sheets and are produced from steel coils which are hot dipped galvanized, and with a minimum of AZ150 zinc-aluminum coating on it.
Roof & Wall Sheeting
- Tensile Strength – 550 MPA
- Thickness Range – 0.3 mm to 0.8 mm
- Effective Width – 1000 mm
Paramount
Sandwich Panel
Paramount sandwich panels provide substantial savings on equipment and operation to control the climate of the building from heating or cooling. They are available in thicknesses ranging from 30 mm to 120 mm. They are most durable and can be resistant to any kind of harsh weather conditions.
Paramount Standing Seam Roof System
Paramount double lock standing seam system, eliminates the risk of leakage at fasteners at side and end provides excellent protection in all weather conditions by having one full length panel running end to end. It assures consistent weather tightness with virtually maintenance free performance for many years.
Standing Seam Roof Sheeting
- Tensile Strength – 345 MPA
- Thickness Range – 0.5 mm to 0.6 mm
- Effective Width – 608.08 mm
Standard Sheeting Colors
Paramount Deck Sheeting
Paramount Deck Sheet is used as a composite floor system. The steel deck profile sheet has a ribbed profile with embossment to interlock with concrete slabs, creating a reinforced concrete slab that serves dual purpose of permanent form and positive reinforcement.
ParaDeck 52
- Effective width – 972 mm
- Thickness Range – 0.8 mm to 1.2 mm
Trims / Flashings
Standard Flashing
Drip Flashing / End Wall Flashing
Gable Flashing / Barge Flashing
Valley Gutter
Eave Gutter
Corner Flashing
PEB Accessories
Paramount’s standard louvers are 1m(W) X 1m(H) & 2m(W) X 1m(H). Non- standard sizes can also be provided on request
Paramount’s standard sky lights/wall lights are 2 mm thick Polycarbonate sheets with size 1.0 M X 3.0 M. Non-standard lengths are available on request.
Paramount’s standard comes in two variations either in FRP or Polycarbonate with 600 mm dia.
Paramount’s standard ridge ventilators are of 0.3 M throat width and can be supplied either continuous or in modules of 3.0 M length.
Fiberglass roof curbs will be provided power ventilators at the ridge are required. Roof curbs are also supplied, if requested by customers, to support roof mounted fans or other equipment.
Standard Single or Double sliding doors are of sizes varying from 3.0M X 3.0M to 5.0M X 5.0M. Paramount can also offer any other bigger size if required by the customers.
We supply different type of insulations as mentioned below based on clients requirement
- Fibre glass Insulation
- Rock Wool Insulation
- XLPE Insulation
- Fibre glass Insulation